"Dịch vụ của chúng tôi - Sự tin tưởng của bạn"
Sản phẩm
Miniature Circuit Breaker (MCB)
Compact NS
Compact NS80H MA is specially designed for the protection of motors rated up to 37kW thus guaranteeing absolute peace of mind.
  • Dedicated protection.
  • Service continuity.
Features:
  • Nominal current: 80 A.
  • Breaking performance: 70 kA at 380/415 V.
  • Voltage rating: 690 V.
  • 3-pole version.
  • Installation on mounting plate or DIN rail.
  • Built-in magnetic trip unit.
  • Instantaneous protection adjustable from 6 to 14 In.
  • Compliance with international standard IEC 60947-2.
NG125LMA
The NG125LMA circuit breaker - motor protection Miniature Circuit Breaker up to 80A -  combines performance and robustness required in the most demanding industrial installations.
  • Rating current: 4 to 80 A.
  • Breaking capacities: 50kA under 380/415 V.
  • Tripping curves: MA (short-circuit protection to combine with suitable overload protection).
  • Compliance with standards: IEC 60947-2, certified by national official authorities; NG125LMA + Telemecanique contactor and thermal relay combination in compliance with IEC 60947-4.
  • Suitable for isolation in accordance with industrial standards: IEC 60947.
  • Operating voltage: up to 500 Vac, insulation voltage: 690V.
  • Optional add-on earth leakage modules: Vigi NG125.
  • Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip.
TeSys
TeSys GV2 - Magnetic and thermal magnetic motor circuit breakers up to 15 kW.
  • Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor.
  • Protection provided by thermal-magnetic devices built into the circuit breaker.
  • The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost.
  • The addition of a shunt trip enables remote control of tripping.
  • The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks.
  • Connectors: spring terminal, screw clamp.
 
TeSys GV3 - Magnetic and thermal magnetic motor circuit breakers up to 30 kW - can be easily integrated with all configurations .
 
GV3 P Thermal-Magnetic Breaker:
  • 7 ratings from 9 to 65 A used for magnetic and thermal motor protection from 5.5 to 30 kW.
GV3 L Magnetic Breaker:
  • 5 ratings from 25 to 65 A used for magnetic motor protection from 11 to 30 kW.
  • Common characteristics:
  • 50 kA Icu breaking capacity from 40 to 65A and 100 kA Icu from 9 to 32 A, complying with international standards and certifications.
  • Product compacity: 55 mm width provides an easier installation in the panel and space saving, mounting on DIN rail.
  • Sturdiness and safety with 3-position rotary handle, front face padlocking.
 
 
TeSys GV7 - Thermal magnetic motor circuit breakers up to 110 kW
  • Rocker lever control.
  • Models: GV7-RE, GV7-RS.
  • 8 ratings.
  • Optional door-mounted control.
  • Short-circuit trip threshold: average 13 In.
  • Rated current with 415 V: 12…220 A.
  • Breaking capacity with 415 V (Icu) in accordance with IEC 947-2: 25…70 kA.
  • Connectors: screw clamp.